718D, Sensorless control commutation position lost
The commutation position deviation exceeds the configured threshold.
| 
									 Diagnostic Code (Hex.)  | 
									 Diagnostic Code (Dez.)  | 
|---|---|
| 
									 718D  | 
									 29069  | 
| 
									 Class  | 
									 Type  | 
|---|---|
| 
									 Error  | 
									 Error  | 
| 
									 Standard Reaction  | 
									 Reset  | 
|---|---|
| 
									 Shorted coils brake  | 
									 Execute Reset-Command (Fault reset).  | 
| 
									 Possible Causes  | 
									 Solutions  | 
|---|---|
| 
									 The commutation position deviation exceeds the configured threshold.  | 
									 Check sensorless control parameter settings.  | 
Internal: 0x718D, Sensorless control commutation position lost