7888, EnDat3: Encoder start failed, Id=0xXX, Arg=0xXX
The start sequence of the encoder processing failed:
				
				Id=0x01: Enocder start failed with internal error code (Arg='Internal error code'')
				Id=0x08: Encoder file processing error. Arg=Internal Id
				Id=0x0C: Encoder start failed. Start sequence aborted in step = 'Arg'
				Id=0x0D: Encoder start failed. Arg=1: Pointer not allocated, Arg=2: Invalid Fpga, Arg=3: Internal error, Arg=4: MeasuringStepsPerRev or MeasuringStepLength == 0, Arg=5: Internal error, Arg=6: Init position processing failed, Arg=7: MeasuringStepsPerRev or MeasuringStepLength == 0
| 
									 Diagnostic Code (Hex.)  | 
									 Diagnostic Code (Dez.)  | 
|---|---|
| 
									 7888  | 
									 30856  | 
| 
									 Class  | 
									 Type  | 
|---|---|
| 
									 Error  | 
									 Feedback error  | 
| 
									 Standard Reaction  | 
									 Reset  | 
|---|---|
| 
									 Axis is inoperable  | 
									 Execute Reset-Command (Fault reset).  | 
| 
									 Possible Causes  | 
									 Solutions  | 
|---|---|
| 
									 
  | 
									 
  | 
Internal: 0x7888, EnDat3: Encoder start failed, Id=0x%X, Arg=0x%X