73C0, EnDat22: Encoder error (position invalid), Id=0xXX, Arg=0xXX
The encoder position (first feedback) is invalid:
				
				Id=1: Got no valid position from the EnDat-Ip-Core. Arg = 'Internal status word'
				
				'Internal status word':
				Bit  0: PositionReady : The position is ready to use.
				Bit  1: PositionTimeout : Timeout exceeded.
				Bit  2: EnDatSt_Error1 : The EnDat-IpCore signals Error 1
				Bit  3: EnDatSt_Crc : The EnDat-IpCore signals an Crc-Error
				Bit  4: EnDatSt_ErrorHandlerType1active
				Bit  5: EnDatSt_ErrorHandlerType2active
				Bit  6: EnDatSt_MrsAdrError
				Bit  7: EnDatSt_NotError2 : The EnDat-IpCore signals NOT Error 2
				Bit  8: EnDatSt_CrcErrorZ1 : The EnDat-IpCore signals an Crc-Error for the 'Additional Data 1'
				Bit  9: EnDatSt_CrcErrorZ2 : The EnDat-IpCore signals an Crc-Error for the 'Additional Data 2'
				Bit 10: EnDatSt_ReferenceLatched
				Bit 11: EnDatSt_Warning
				Bit 12: EnDatSt_ErrorHandlerType3active
				Bit 13: rsvd
				Bit 14: rsvd
				Bit 15: rsvd
| 
									 Diagnostic Code (Hex.)  | 
									 Diagnostic Code (Dez.)  | 
|---|---|
| 
									 73C0  | 
									 29632  | 
| 
									 Class  | 
									 Type  | 
|---|---|
| 
									 Error  | 
									 Feedback error  | 
| 
									 Standard Reaction  | 
									 Reset  | 
|---|---|
| 
									 Open loop ramp  | 
									 Execute Reset-Command (Fault reset).  | 
Internal: 0x73C0, EnDat22: Encoder error (position invalid), Id=0x%X, Arg=0x%X