7398, Physical position sensor required
|
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
|---|---|
|
7398 |
29592 |
|
Class |
Type |
|---|---|
|
Error |
Error |
|
Standard Reaction |
Reset |
|---|---|
|
Open loop ramp |
Execute Reset-Command (Fault reset). |
|
Possible Causes |
Solutions |
|---|---|
|
Physical position sensor is required for selected motor control mode but no suitable sensor is configured. |
Check position sensor and motor control mode configuration. |
Internal: 0x7398, Physical position sensor required