8180, System restart or sync lost
| 
									 Diagnostic Code (Hex.)  | 
									 Diagnostic Code (Dez.)  | 
|---|---|
| 
									 8180  | 
									 33152  | 
| 
									 Class  | 
									 Type  | 
|---|---|
| 
									 Error  | 
									 Error  | 
| 
									 Standard Reaction  | 
									 Reset  | 
|---|---|
| 
									 Closed loop ramp  | 
									 Execute Reset-Command (Fault reset).  | 
| 
									 Possible Causes  | 
									 Solutions  | 
|---|---|
| 
									 The Slave has received no ProcessData for more than one EtherCAT Cycle.  | 
									 Check the realtime Tasks of your EtherCAT Master.  | 
Internal: 0x8180, System restart or sync lost