2386, Motor brake current offset out of range
The measured current offset of the motor brake is outside the accepted range.
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
---|---|
2386 |
9094 |
Class |
Type |
---|---|
Error |
Error |
Standard Reaction |
Reset |
---|---|
Torque off |
A reset is not possible. The drive detected a fatal hard- or software error. |
Possible Causes |
Solutions |
---|---|
An unknown hard- or software error has occurred. |
Disconnect the power supply module from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff support that is responsible for you. |
The device might be influenced by an external magnetic field. |
Check the environment of this device for magnetic components. |
Internal: 0x2386, Motor brake current offset out of range