P-0-0010 Feature flags
Feature flags are used to configure backward compatible behavior. Setting a bit is enabling extended functionality.
Attributes
|
Name |
Value |
|---|---|
|
Datatype |
binary |
|
Data length in bit |
64 |
|
Decimal point |
- |
|
Min. Value |
- |
|
Default |
firmware depending |
|
Max. Value |
- |
|
Unit |
- |
|
Changeable in EtherCAT state |
PreOp |
|
Cyclic transfer |
No |
|
Device parameter |
No |
|
Related to interface revision |
changed from Rev. 210 |
Parameter structure:
|
Bit |
Description |
|---|---|
|
0 |
Enable adjusted velocity controller gain scaling |
|
1 |
Enable adapted axis state machine |
|
2 |
View enlarged error history |
|
3 |
Enable excessive position deviation monitoring |
|
4 |
View extended software versions list (P-0-0320) |
|
5 |
Enable extended power management |
|
6 |
Consider ‘the additive position command value’ (S-0-0048) |
|
7 |
rsvd |
|
8 |
Enable switching frequency reduction |
|
9 |
Enable phase clamping |
|
10 |
Explicit modulo init data saving required |
|
11 |
Probe unit: Hardware delay compensation |
|
12 |
Feedback value sampling point: Adjusted to sync1 |
|
13 |
Set data length of P-0-0070 to 4 byte (from Rev. 210) |
|
14 |
Extended thermal motor model P-0-0062 (from Rev. 210) |
|
15 |
Velocity controller gain in Nm / (rad/s) (from Rev. 210) |
|
16 |
Acceleration feed forward gain (S-0-0348) in “%” (from Rev. 210) 0 = No |
|
17-63 |
Reserved (from Rev. 210) |