P-0-0219 External braking resistor peak utilization
This parameter provides the maximal seen value of the averaged actual continuous power of the optional external braking resistor (P-0-0210) since booting the drive like a drag indicator.
Attributes
|
Name |
Value |
|---|---|
|
Datatype |
udec |
|
Data length in bit |
16 |
|
Decimal point |
1 |
|
Min. Value |
- |
|
Default |
0.0 |
|
Max. Value |
- |
|
Unit |
% |
|
Changeable in EtherCAT state |
No |
|
Cyclic transfer |
AT |
|
Device parameter |
No |
|
Related to interface revision |