P-x-0205 Power management status word
This parameter displayes the actual internal state of power management and can be used for diagnostic purposes.
Attributes
Name | Value |
|---|---|
Datatype | binary |
Data length in bit | 16 |
Decimal point | 0 |
Min. Value | 0 |
Default | 0 |
Max. Value | - |
Unit | - |
EtherCATState | - |
Cyclic transfer | AT |
Device parameter | Yes |
Related to interface revision | changed from Rev. 210 |
![]() | Included in the “Parameter Set Switching” function group! This IDN exists as P-0-0205 - P-7-0205. |
Parameter structure
Bit | Description |
|---|---|
0 | Status Umains ok |
1 | Umains Overvoltage |
2 | Umains phase error |
3 | Status DC Link ok |
4 | Ext. Umains relay |
5 | Status fan |
6 | Status circuit |
7 | Status internal chopper |
8 | Status external chopper |
9 | Status additional fan |
10 | Extended power management (see P-0-0010, Bit 5) |
11 | Umains loss monitoring enabled |
12 | Umains loss (from Rev. 210) |
13--15 | Reserved (from Rev. 210) |