P-x-0119 ASM: Boost voltage slope
This IDN configures the induction motor boost voltage slope.
Attributes
| 
 Name  | 
 Value  | 
|---|---|
| 
 Datatype  | 
 udec  | 
| 
 Data length in bit  | 
 32  | 
| 
 Decimal point  | 
 3  | 
| 
 Min. Value  | 
 10.000  | 
| 
 Default  | 
 80000.000  | 
| 
 Max. Value  | 
 160000.000  | 
| 
 Unit  | 
 V/s  | 
| 
 Changeable in EtherCAT state  | 
 PreOp  | 
| 
 Cyclic transfer  | 
 No  | 
| 
 Device parameter  | 
 No  | 
| 
 Related to interface revision  | 
 No  | 
![]()  | Included in the “Parameter Set Switching” function group! This IDN exists as P-0-0119 - P-7-0119.  | 