S-0-0405 Probe 1 enable
This parameter is used to activate probe unit 1 of the drive. This parameter can be linked with a real-time control bit (S-0-0301), so that activation is possible via the MasterControlWord (S-0-0134).
Attributes
|
Name |
Value |
|---|---|
|
Datatype |
binary |
|
Data length in bit |
16 |
|
Decimal point |
0 |
|
Min value |
- |
|
Default |
0 |
|
Max value |
- |
|
Unit |
- |
|
Changeable in EtherCAT state |
PreOp, SafeOp, Op |
|
Cyclic transfer |
MDT |
|
Device parameter |
No |
|
Related to interface revision |
No |
The drive checks this parameter as long as S-0-0170 is enabled. To start a new measuring probe cycle, the value of this IDN must be changed from 0 to 1.
Bit pattern:
|
Bit |
Meaning |
|---|---|
|
0 |
Probe 1 |
|
1 – 15 |
Reserved |
![]() | For further information please look into the involved IDN: |
![]() | Additional functional description AX5000 / Probe Unit |