S-0-0267 Password
The parameter can be used to enable or disable write protection for password-protected IDNs. (The interface) EtherCAT supports passwords to protect selected parameters.
Attributes
|
Name |
Value |
|---|---|
|
Datatype |
text |
|
Data length in bit |
272 |
|
Decimal point |
0 |
|
Min value |
- |
|
Default |
AX5000 |
|
Max value |
- |
|
Unit |
- |
|
Changeable in EtherCAT state |
PreOp, SafeOp, Op |
|
Cyclic transfer |
No |
|
Device parameter |
No |
|
Related to interface revision |
No |
The password write protection is disabled if
- this parameter sent to the drive with the valid password. Parameters with password write protection can then be changed.
The password write protection is disabled if
- the power supply of the drive is initially interrupted, then restored, or
- if this parameter is sent to the drive without a valid password.
Password levels 1 and 2 exist for AX5000.
Please contact Beckhoff support regarding passwords for password write protection.
Note | |
Possible damage and failures caused by changes in password-level 2 Great care must be taken when making changes in IDNs protected in this way, because a zero offset of the measuring system, for example, could be overwritten irrevocably. |
![]() | Nested structure Note the nesting depth and the structure information at the start of the descriptions. |