S-0-0216 Switch parameter set (pc)
The parameter contains the parameter set switchover command. This command can be used to switch between different data sets of a parameter set. The drive switches to the data set that is specified with S-0-0217.
Attributes
| 
 Name  | 
 Value  | 
|---|---|
| 
 Datatype  | 
 binary  | 
| 
 Data length in bit  | 
 16  | 
| 
 Decimal point  | 
 0  | 
| 
 Min value  | 
 -  | 
| 
 Default  | 
 0  | 
| 
 Max value  | 
 -  | 
| 
 Unit  | 
 -  | 
| 
 Changeable in EtherCAT state  | 
 Op  | 
| 
 Cyclic transfer  | 
 No  | 
| 
 Device parameter  | 
 No  | 
| 
 Related to interface revision  | 
 No  | 
Bit pattern:
| 
 Bit  | 
 Meaning  | 
|---|---|
| 
 0  | 
 Cancel cmd 0 = disable  | 
| 
 1  | 
 Set cmd 0 = disable  | 
| 
 2  | 
 Reserved  | 
| 
 3  | 
 Set & enable command 0 = disable  | 
| 
 4 -15 
  | 
 Reserved  | 
![]()  | For further information please look into the involved IDN:  | 