S-0-0204 Motor shut down temperature
If the temperature of the motor exceeds this value, the drive sets error bit 2 of S-0-0011, and an error is generated. FD07 "Motor overtemperature shutdown" is issued as the corresponding error code.
Attributes
|
Name |
Value |
|---|---|
|
Datatype |
udec |
|
Data length in bit |
16 |
|
Decimal point |
1 |
|
Min value |
0.0 |
|
Default |
100.0 |
|
Max value |
150.0 |
|
Unit |
°C |
|
Changeable in EtherCAT state |
PreOp |
|
Cyclic transfer |
No |
|
Device parameter |
No |
|
Related to interface revision |
No |
![]() | For further information please look into the involved IDN: |