S-0-0200 Amplifier warning temperature
If the temperature in the AX5000 exceeds this value, the drive sets change bit 1 of S-0-0012, and a warning is generated.
Attributes
Name | Value |
|---|---|
Data type | udec |
Data length | 16 |
Decimal point | 1 |
Min value | 40.0 |
Max value | 80.0 |
Default | 70.0 |
Unit | °C |
Changeable in EtherCAT state | No |
Cyclic transfer | No |
Device parameter | Yes |
Related to interface revision | No |
![]() | IDNs involved |