S-0-0169 Probe control parameter
The parameter specifies which edges are activated by the command S-0-0170.
Attributes
|
Name |
Value |
|---|---|
|
Datatype |
binary |
|
Data length in bit |
16 |
|
Decimal point |
0 |
|
Min value |
- |
|
Default |
0.0 |
|
Max value |
- |
|
Unit |
- |
|
Changeable in EtherCAT state |
PreOp, SafeOp, Op |
|
Cyclic transfer |
No |
|
Device parameter |
No |
|
Related to interface revision |
No |
Bit pattern:
|
Bit |
Meaning |
|---|---|
|
0 |
Probe 1 positive edge 0 = positive edge is not active |
|
1 |
Probe 1 negative edge 0 = negative edge is not active |
|
2-4 |
Reserved |
|
5 |
Mode probe 1 0 = individual measurement |
|
6-7 |
Reserved |
|
8 |
Auto activation 0 = activation with S-0-0170 |
|
9 - 15 |
Reserved |
![]() | For further information please look into the involved IDN: |