S-0-0149 Positive drive stop procedure command (pc)

The parameter contains the command: “Travel to fixed stop.” This command disables following error monitoring of the drive.

Attributes

Name

Value

Data type

binary

Data length

16

Decimal point

0

Min value

-

Max value

-

Default

-

Unit

-

Changeable in EtherCAT state

SafeOp and Op

Cyclic transfer

No

Device parameter

No

Related to interface revision

 

“Set and activate command” results in all monitoring being switched off, which otherwise would lead to a drive error S-0-0011 (drive shut down) if the drive is blocked by a fixed stop.
The command is confirmed positively if the following is true:
– |T | ≥ |Tlimit| (T_limit corresponds to the effective maximum or minimum of S-x-0092, S-x-0082, and S-x-0083 here.)
– The actual speed is within the standstill window (nfeedback = 0)
When the command ends, all monitoring settings are restored to their original state.

Bit pattern:

Bit

Meaning

0

Cancel cmd
0 = Cancel command

Set cmd
1 = Set command

0–1

Set & enable command
3 = Set and activate command

2–15

 