FD21, Motor management: Voltage error
The mains voltage range entered is not permissible for the field weakening operation with synchronous motors.
| Diagnostic Code (Hex.) | Diagnostic Code (Dez.) | 
|---|---|
| FD21 | 64801 | 
| Class | Type | 
|---|---|
| Error | Parameter error | 
| Standard Reaction | Reset | 
|---|---|
| The power stage is already switched off | Execute Reset-Command (S-0-0099). | 
| Possible Causes | Solutions | 
|---|---|
| The permissible range of the voltage value for the field weakening operation "U_mains-min and U_mains-max" of the IDN P-0-455 is calculated during initialization and compared with the parametrized value in the IDN P-0-0201. | "U_mains-min" less than (P-0-0201 minus P-0-0203) and "U_mains-max" greater than (P-0-0201 plus P-0-0202). Check the IDNs for plausible values. | 
| Further Information | 
|---|
| AX5000_IDN-Description: "P-0-0201; P-0-0202; P-0-0203 and P-0-0455" |