FD20, Motor management: Invalid motor data.
Motor data are missing for the calculation of the motor characteristic curve.
|
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
|---|---|
|
FD20 |
64800 |
|
Class |
Type |
|---|---|
|
Error |
Parameter error |
|
Standard Reaction |
Reset |
|---|---|
|
The power stage is already switched off |
Execute Reset-Command (S-0-0099). |
|
Possible Causes |
Solutions |
|---|---|
|
If at least one of the following functions - speed limitation (P-0-0451), current limitation (P-0-0451) or field weakening operation (P-0-0455) - is activated, the following parameters must be valid. |
Check the following IDNs: P-0-0055; P-0-0066; P-0-0070; P-0-0073; P-0-0077 and S-0-0196 (If no rated motor current is entered, the motor standstill current is used). |
|
Further Information |
|---|
|