FC37, Internal communication error
Communication error via I2C between the modules of the servo drive
|
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
|---|---|
|
FC37 |
64567 |
|
Class |
Type |
|---|---|
|
Error |
Runtime error |
|
Standard Reaction |
Reset |
|---|---|
|
Closed loop ramp |
Execute Reset-Command (S-0-0099). |
|
Possible Causes |
Solutions |
|---|---|
|
There is an internal hardware error. |
Send the AX5000 to the Beckhoff branch office that is responsible for you. |