F876, Feedback "EnDat 2.2": UART-error
EnDat 2.2 - UART-error
|
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
|---|---|
|
F876 |
63606 |
|
Class |
Type |
|---|---|
|
Error |
Runtime error |
|
Standard Reaction |
Reset |
|---|---|
|
Open loop ramp |
Execute Reset-Command (S-0-0099). |
|
Possible Causes |
Solutions |
|---|---|
|
The feedback system is defective. |
Check the feedback system. |
|
The plug connection of the feedback line is defective. |
Check the plug connection. |
|
The feedback line is defective. |
Check the feedback line. |