F73E, Feedback "general": Data transfer failed.
Too many errors occurred during the data transmission on the feedback parameter channel.
|
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
|---|---|
|
F73E |
63294 |
|
Class |
Type |
|---|---|
|
Error |
Runtime error |
|
Standard Reaction |
Reset |
|---|---|
|
Open loop ramp |
Execute Reset-Command (S-0-0099). |
|
Possible Causes |
Solutions |
|---|---|
|
The feedback line is defective. |
Check the line. |
|
Wrong feedback system. |
Enter the correct feedback system. |
|
The feedback system is defective. |
Check the feedback system. |
|
An unknown hard- or software error has occurred. |
Disconnect the servo drive from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff branch office that is responsible for you. |