F716, Internal communication: SPI - Front card to Option card
The general communication of the interface between the front card and the option card has failed due to an internal data fault (Got no timer).
|
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
|---|---|
|
F716 |
63254 |
|
Class |
Type |
|---|---|
|
Error |
Runtime error |
|
Standard Reaction |
Reset |
|---|---|
|
Closed loop ramp |
Execute Reset-Command (S-0-0099). |
|
Possible Causes |
Solutions |
|---|---|
|
An unknown hard- or software error has occurred. |
Disconnect the servo drive from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff branch office that is responsible for you. |