63B6, Parameter Torque Control: Invalid device total output current sum
The device total output current sum is to high. (Sum of all axes.)
|
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
|---|---|
|
63B6 |
25526 |
|
Class |
Type |
|---|---|
|
Error |
Error |
|
Standard Reaction |
Reset |
|---|---|
|
Axis is inoperable |
Execute Reset-Command (Fault reset). |
|
Possible Causes |
Solutions |
|---|---|
|
The configured rated current sum is higher than accepted by the device. |
Please check the configured rated current parameters of all axes. |
|
The configured peak current sum is higher than accepted by the device. |
Please check the configured peak current parameters of all axes. |
|
The configured current sum is higher than accepted by the device because of a pwm mode considered derating. |
Please check the configured pwm mode parameters of all axes. |
Internal: 0x63B6, Parameter Torque Control: Invalid device total output current sum