5590, Detected incompatible Pcb
Detected incompatible Pcb for this Firmware.
				- ID 0: ControlPcb
				- ID 1: FrontPcb
				- ID 2: AdditionalAxisPcb
				- ID 3: DisplayPcb
				- ID 6: SafetyPcb
				- ID 7: CpuPcb
| 
									 Diagnostic Code (Hex.)  | 
									 Diagnostic Code (Dez.)  | 
|---|---|
| 
									 5590  | 
									 21904  | 
| 
									 Class  | 
									 Type  | 
|---|---|
| 
									 Error  | 
									 Error  | 
| 
									 Standard Reaction  | 
									 Reset  | 
|---|---|
| 
									 Torque off  | 
									 A reset is not possible. The drive detected a fatal hard- or software error.  | 
| 
									 Possible Causes  | 
									 Solutions  | 
|---|---|
| 
									 This Hardware is unsupported of this Firmware.  | 
									 Disconnect the power supply module from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff support that is responsible for you.  | 
| 
									 The HardwareType is unknown.  | 
									 Disconnect the power supply module from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff support that is responsible for you.  | 
| 
									 The HardwareRevision is unsupported.  | 
									 Disconnect the power supply module from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff support that is responsible for you.  | 
Internal: 0x5590, Detected incompatible Pcb at ID %u.