ULARGE_INTEGER

ULARGE_INTEGER 1:

The function initializes a TwinCAT 2 unsigned 64-bit number (“legacy” type: T_ULARGE_INTEGER).

ULARGE_INTEGER 2: Return value

Name

Type

Description

ULARGE_INTEGER

T_ULARGE_INTEGER

 

ULARGE_INTEGER 3: Inputs

VAR_INPUT
    dwHighPart : DWORD;
    dwLowPart  : DWORD;
END_VAR

Name

Type

Description

dwHighPart

DWORD

Upper 32 bits

dwLowPart

DWORD

Lower 32 bits

Requirements

Development environment

Target platform

PLC libraries to be integrated (category group)

TwinCAT v3.1.0

PC or CX (x86, x64, Arm®)

Tc2_Utilities (System)