TC_Stop

TC_Stop 1:

The function block TC_Stop can be used to stop the TwinCAT system. The function corresponds to the Stop command on the TwinCAT system menu (on the right of the Windows taskbar).

TC_Stop 2: Inputs

VAR_INPUT
    NETID  : T_AmsNetId;
    STOP   : BOOL;
    TMOUT  : TIME := DEFAULT_ADS_TIMEOUT;
END_VAR

Name

Type

Description

NETID

T_AmsNetID

A string with the network address of the TwinCAT computer on which the TwinCAT system stop is to be executed can be specified here. If the TwinCAT system to be stopped is on the local computer, an empty string can be entered.

STOP

BOOL

The function block is enabled by a positive edge at this input.

TMOUT

TIME

Time-out period that may not be exceeded when executing the ADS command.

TC_Stop 3: Outputs

VAR_OUTPUT
    BUSY   : BOOL;
    ERR    : BOOL;
    ERRID  : UDINT;
END_VAR

Name

Type

Description

BUSY

BOOL

When the function block is enabled, this output is set and remains set until a feedback is received.

ERR

BOOL

If an ADS error should occur during the transfer of the command, then this output is set once the BUSY output is reset.

ERRID

UDINT

Returns the ADS error number when the ERR output is set.

Requirements

Development environment

Target platform

PLC libraries to be integrated (category group)

TwinCAT v3.1.0

PC or CX (x86, x64, ARM)

Tc2_Utilities (System)