PLC_ReadSymInfo
The "PLC_ReadSymInfo" function block permits information regarding the symbols (variables) of a PLC run-time system.
VAR_INPUT
VAR_INPUT
NETID : T_AmsNetId;
PORT : T_AmsPort;
START : BOOL;
TMOUT : TIME := DEFAULT_ADS_TIMEOUT;
END_VAR
NETID: It is possible here to provide the AmsNetId of the TwinCAT computer whose symbol information is to be found (type: T_AmsNetID). If it is to be run on the local computer, an empty string can be entered.
PORT: The port number of a PLC run-time system (type: T_AmsPort).
START: the block is activated by a positive edge at this input.
TMOUT: States the length of the timeout that may not be exceeded by execution of the ADS command.
VAR_OUTPUT
VAR_OUTPUT
BUSY : BOOL;
ERR : BOOL;
ERRID : UDINT;
SYMCOUNT : UDINT;
SYMSIZE : UDINT;
END_VAR
BUSY: When the function block is activated this output is set. It remains set until a feedback is received.
ERR: If an error should occur during the transfer of the command, then this output is set once the BUSY output was reset.
ERRID: Supplies the ADS error number when the ERR output is set.
SYMCOUNT: The number of symbols in the PLC run-time system.
SYMSIZE: Length of the data, in bytes, in which the symbol information is stored.
Requirements
Development environment |
Target platform |
PLC libraries to be integrated (category group) |
---|---|---|
TwinCAT v3.1.0 |
PC or CX (x86, x64, ARM) |
Tc2_Utilities (System) |