IOF_GetDeviceCount

IOF_GetDeviceCount 1:

The IOF_GetDeviceCount function block reads the number of configured and active I/O devices.

IOF_GetDeviceCount 2: Inputs

VAR_INPUT
    NETID     : T_AmsNetId;
    START     : BOOL;
    TMOUT     : TIME := DEFAULT_ADS_TIMEOUT;
END_VAR

Name

Type

Description

NETID

T_AmsNetId

The network address of the TwinCAT computer on which the ADS command is to be executed can be specified here. For the local computer an empty string may be specified.

START

BOOL

The function block is enabled by a positive edge at this input.

TMOUT

TIME

Specifies the time-out period that must not be exceeded when the command is executed.

IOF_GetDeviceCount 3: Outputs

VAR_OUTPUT
    BUSY        : BOOL;
    ERR         : BOOL;
    ERRID       : UDINT;
    DEVICECOUNT : UDINT;
END_VAR

Name

Type

Description

BUSY

BOOL

When the function block is enabled, this output is set and remains set until a feedback is received.

ERR

BOOL

If an error should occur during the transfer of the command, then this output is set once the BUSY output was reset.

ERRID

UDINT

Returns the ADS error number when the ERR output is set.

DEVICECOUNT

UDINT

Number of I/O devices

Requirements

Development environment

Target platform

IO hardware

PLC libraries to be integrated (category group)

TwinCAT v3.1.0

PC or CX (x86, x64, ARM)

All IO devices

Tc2_IoFunctions (IO)