Roller replacement at AT9014-0055-x550
Dedicated roller sets are available for maintenance of the movers AT9014‑0055‑x550. A roller set contains all the components required for replacement.
![]() | One time roller replacement To ensure high availability of the system, the rollers on this mover may only be replaced once every 30,000 km. After another 30,000 km, the base body and the rollers must be replaced. The previously installed magnetic plate set can continue to be used. |
The following accessories are available for replacing the base body with the rollers after 60,000 km:
- ZX9014-0155
If the magnetic plate set of the previous mover is to be reused, the magnetic plate set on the previous mover must be removed and fitted to the new base body. Further information can be found in chapter Replacing the magnetic plates.
![]() | ESD brush replacement The ESD brush of the mover must be replaced after disassembling the rollers. |