Transformation editor

Six different types of transformation can be defined with this dialog:

Items

List of all objects added

Transformation editor 1:

Delete the selected object

Transformation editor 2:

Change the object order (top = left)

Transformation editor 3:

Add a new object

Translate

Name

Description

X

Definition of the distance by which the control is to be shifted in the X direction

Y

Definition of the distance by which the control is to be shifted in the Y direction

Z

Definition of the distance by which the control is to be shifted in the Z direction

Rotate

Name

Description

Angle

Definition of an angle by which the control is to be rotated

Angle Unit

Selection of the unit of the angle:

  • Deg: Degrees (full circle = 360 deg)
  • Rad: Radians (full circle = 2*Pi*Radians)
  • Turn: Number of turns (full circle = 1 turn)
  • Grad: Gon (full circle = 400 grad)

Vector X

Definition of the X component of the vector

Vector Y

Definition of the Y component of the vector

Vector Z

Definition of the Z component of the vector

Scale

Name

Description

X

Definition of the zoom factor in the X direction

Y

Definition of the zoom factor in the Y direction

Z

Definition of the zoom factor in the Z direction

Skew

Name

Description

X Angle

Definition of the angle by which the vertical sides are to be skewed

X Angle Unit

Selection of the unit of the angle:

  • Deg: Degrees (full circle = 360 deg)
  • Rad: Radians (full circle = 2*Pi*Radians)
  • Turn: Number of turns (full circle = 1 turn)
  • Grad: Gon (full circle = 400 grad)

Y Angle

Definition of the angle by which the horizontal sides are to be skewed

Y Angle Unit

Selection of the unit of the angle:

  • Deg: Degrees (full circle = 360 deg)
  • Rad: Radians (full circle = 2*Pi*Radians)
  • Turn: Number of turns (full circle = 1 turn)
  • Grad: Gon (full circle = 400 grad)

Origin

Name

Description

X

Definition of the X coordinate of the origin of the transformations

X Unit

Selection of the unit of the coordinate:

  • Pixels for an absolute position
  • Percent for a relative position

Y

Definition of the Y coordinate of the origin of the transformations

Y Unit

Selection of the unit of the coordinate:

  • Pixels for an absolute position
  • Percent for a relative position

Z

Definition of the Z coordinate of the origin of the transformations

Z Unit

Selection of the unit of the coordinate:

  • Pixels for an absolute position
  • Percent for a relative position

Perspective

Name

Description

Distance

Definition of the distance of the perspective

Distance Unit

Selection of the unit of the coordinate:

  • Pixels for an absolute position
  • Percent for a relative position

Origin X

Definition of the X coordinate of the origin of the perspective

Origin X Unit

Selection of the unit of the coordinate:

  • Pixels for an absolute position
  • Percent for a relative position

Origin Y

Definition of the Y coordinate of the origin of the perspective

Origin Y Unit

Selection of the unit of the coordinate:

  • Pixels for an absolute position
  • Percent for a relative position