Solution Explorer

The Solution Explorer manages all available projects in a Solution. After creating a new TwinCAT HMI project the following project structure is constructed:

Solution Explorer 1:
  1. TcHmiProject: The project node offers access to the Project Settings.
  2. Server: The server node contains the Server Settings and lists the loaded server extensions.
  3. Framework: The framework node enables the referencing of Framework Controls.
  4. Properties: Lists the internal configuration files of the project.
  5. References: Offers the option to reference TwinCAT HMI packages.
  6. Imports: Folder for contents such as images or videos that are added dynamically (e.g. by drag-and-drop via the Gallery Explorer).
  7. Themes: The folder contains all themes that have been added to the project.
  8. Fonts: This folder contains fonts that apply irrespective of the theme.
  9. Images: Folder for images.
  10. Localization: This folder contains the language files required for the project.
  11. Desktop.view: The start page that is displayed when starting the HMI.
  12. FavIcon.ico: The icon displayed in the title bar of the browser.