Saving license files manually on the dongle

The license file to be copied to the dongle can be located in any directory.
Up to 20 license files with a total volume of up to 1 MB can be saved on the dongle.
1. Update first the dongle status to ensure that TwinCAT Engineering can access the current dongle (see also Determining the current status of a license dongle).
2. To copy a license file to the memory of the license dongle, click on Store License on Dongle in the License Device window.
Saving license files manually on the dongle 1:
An Explorer window appears in which you can select the file to save.

Attention: In order to be able to save a License Response File in a TwinCAT 3 license dongle, the file name must be 32 characters long or less.

The current TwinCAT 3 version does not yet provide an overview of the files or licenses stored on the dongle or a function block for program-controlled saving of the file on the license dongle.