Lifetime expectancy

The lifetime expectancy shown in the table indicates the minimum number of operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. The lifetime expectancy is stated in operating hours and is calculated according to the specifications of the capacitor manufacturer. The manufacturer of the electrolytic capacitors only guarantees a maximum life of up to 15 years (131,400h). Any number exceeding this value represents a calculated theoretical lifetime which can be used to compare devices.

 

AC 100V

AC 120V

AC 230V

 

Lifetime expectancy

48,000h

60,000h

94,000h

At 24V, 20A and +40°C

123,000h

149,000h

173,000h

At 24V, 10A and +40°C

23,000h

31,000h

54,000h

At 24V, 24A and +40°C

136,000h

169,000h

265,000h

At 24V, 20A and +25°C

348,000h

422,000h

488,000h

At 24V, 10A and +25°C

64,000h

88,000h

152,000h

At 24V, 24A and +25°C