Output

The output provides an SELV/PELV nominal voltage that is electrically isolated from the input voltage.

The output is designed to supply any type of load, including capacitive and inductive loads. If very large capacitors, such as EDLCs (electrical double-layer capacitors or "UltraCaps") with a capacitance > 0.3F are connected to the output, the device can charge the capacitor intermittently.

The output is electronically protected against overload, no-load and short circuit. In the event of a protection event, audible noises may occur.

Output voltage

Nom.

24V

 

Adjustment range

Min.

24-28V

Guaranteed value

Max.

30.0V

This is the maximum output voltage that can occur in the end position of the potentiometer in clockwise direction due to tolerances. It is not a guaranteed value that can be achieved.

Factory settings

Typ.

24.1V

±0.2% at full load (cold device)

Line regulation

Max.

10 mV

Between 85 and 300Vac

Load regulation

Max.

50 mV

Between 0 and 6A, static value, see Fig. Output voltage over output current, typ.

Residual ripple and ripple voltage

Max.

50mVss

Load >0.2A, bandwidth 20Hz to 20MHz, 50Ohm

Max.

200mVss

Load <0.2A, bandwidth 20Hz to 20MHz, 50Ohm

Output current

Nom.

6A1)

At 24V and an ambient temperature below 45°C, see Fig. Output current over ambient temperature

Nom.

5A

At 24V and 60°C ambient temperature, see Fig. Output voltage over output current, typ.

Nom.

3.8A

At 24V and 70°C ambient temperature, see Fig. Output current over ambient temperature

Nom.

5.1 A1)

At 28V and an ambient temperature below 45°C, see Fig. Output current over ambient temperature

Nom.

4.3A

At 28V and 60°C ambient temperature, see Fig. Output voltage over output current, typ.

Nom.

3.2A

At 28V and 70°C ambient temperature, see Fig. Output current over ambient temperature

Safety
switch-off current

Typ.

15A

For at least 12ms once every five seconds, see Fig. Dynamic output current capacity, typ.
The fuse switch-off current is an increased transient current that contributes to the tripping of fuses on faulty output branches. The output voltage remains above 20V.

Overload behavior

 

Continuous current

Output voltage > 13Vdc, see Fig. Output voltage over output current, typ.

 

Hiccup mode 2)

Output voltage < 13Vdc, see Fig. Output voltage over output current, typ.

Short circuit current

Max.

7.2A

Continuous current, see Fig. Output voltage over output current, typ.

Typ.

9A

Intermittent current peak value for typ. 1s
Load impedance 50mOhm, see Fig. Short circuit at the output,
The discharge current of the output capacitors is not included.

Max.

3.5A

RMS value of current, load impedance 50mOhm, see Fig. Short-circuit at output

Output capacity

Typ.

1800μF

Included in the power supply

Load feedback

Max.

35V

The device is resistant to load feedback and will not indicate a malfunction if a load is feeding voltage back into the power supply. It does not matter whether the power supply is switched on or off. The absorbed energy can be determined by means of the built-in large-size output capacitor.

1) Up to +70°C this power / current can be called up for a duty cycle of 10%, i.e. no longer than 1 minute every 10 minutes.

2) In the event of heavy overload (when the output voltage drops below 13V), the power supply provides continuous output current for 1s. The output is then switched off for about 9 seconds before a new switch-on attempt is automatically made. This cycle is repeated as long as the overload persists. After the overload has been rectified, the device will operate normally. See Fig. Short circuit at output

Output 1:
Output voltage over output current, typ.; Dynamic output current capacity, typ.
Output 2:
Short circuit at output, hiccup mode typ.