Register overview
The registers are used to parameterize the DC motor output stages. They can be read or written by means of register communication.
| Register no. | Comment | Default value | R/W | Memory | |
|---|---|---|---|---|---|
| Status word | 0x0000 | 0dec | R | RAM | |
| Set position | 0x0000 | 0dec | R/W | RAM | |
| Torque | e.g. 0x015E | e.g. 350dec | R | RAM | |
| Supply voltage | e.g. 0x0030 | e.g. 48dec | R | RAM | |
| R4 | reserved | - | - | - | - | 
| Temperature | e.g. 0x0023 | e.g. 35dec | R | RAM | |
| Status byte | e.g. 0x0010 | e.g. 16dec | R | RAM | |
| Command register | 0x0000 | 0dec | R/W | RAM | |
| Terminal type | 0x09EE | 2542dec | R | ROM | |
| Firmware version | e.g. 0x3141 | e.g. 1AASCII | R | ROM | |
| R10 | Multiplex shift register | 0x0130 | 304dec | R | ROM | 
| R11 | Signal channels | 0x0218 | 536dec | R | ROM | 
| R12 | Minimum data length | 0x1800 | 6144dec | R | ROM | 
| R13 | Data structure | 0x0004 | 4dec | R | ROM | 
| R14 | reserved | - | - | - | - | 
| R15 | Alignment register | 0x7F80 | 32640dec | R/W | RAM | 
| Hardware version number | e.g. 0x0000 | e.g. 0dec | R/W | EEPROM | |
| R17 | reserved | - | - | - | - | 
| ... | ... | ... | ... | ... | ... | 
| R30 | reserved | - | - | - | - | 
| Register no. | Comment | Default value | R/W | Memory | |
|---|---|---|---|---|---|
| Code word register | 0x0000 | 0dec | R/W | RAM | |
| Feature register | 0x0000 | 0dec | R/W | EEPROM | |
| User scaling - offset | 0x0000 | 0dec | R/W | EEPROM | |
| User scaling - gain | 0x1000 | 4096dec | R/W | EEPROM | |
| User's switch-on value | 0x0000 | 0dec | R/W | EEPROM | |
| Maximum coil current of the motor | 0x1388 | 5000dec | R/W | EEPROM | |
| Rated current of the motor | 0x0DAC | 3500dec | R/W | EEPROM | |
| Maximum torque | 0x2710 | 10000dec | R/W | EEPROM | |
| Chopper voltage (channel 2 only) | 0x0000 | 0dec | R/W | EEPROM | |
| Internal resistance of the motor | 0x0064 | 100dec | R/W | EEPROM | |
| Automatic switch-off threshold for MixedDecay | 0x0014 | 20dec | R/W | EEPROM | |
| Kp factor | 0x1000 | 4096dec | R/W | EEPROM | |
| Inner window of the I component | 0x0001 | 1dec | R/W | EEPROM | |
| Maximum value of the I component | 0x0005 | 5dec | R/W | EEPROM | |
| Time constant Tn of the I component | 0x0064 | 100dec | R/W | EEPROM | |
| Time constant for deleting or limiting the maximum torque | 0x01F4 | 500dec | R/W | EEPROM | |
| Time constant for limiting the rated motor current | 0x2710 | 10000dec | R/W | EEPROM | |
| R48 | reserved | 
 | 
 | 
 | 
 | 
| ... | ... | ... | ... | ... | ... | 
| R61 | reserved | 
 | 
 | 
 | 
 | 
| Internal parameters for current control | 0x03E8 | 1000dec | R/W | EEPROM | |
| Internal parameters for current control | 0x0064 | 100dec | R/W | EEPROM | |