IP5209 Mapping

Per default setting ex factory the module sends 8 byte process data and 1 byte status (Default: 8 byte process data, 9 byte overall). By changing the Feature Register R32 the process data can be set to 5 byte! In this case the data of the Latch will not be transmitted.

Evaluation in Intel format

Default mapping for CANopen, DeviceNet, Modbus, RS232 and RS485

 

Address

Input data

Output data

Conditions

Word offset

High byte

Low byte

High byte

Low byte

Complete evaluation: don't care
Motorola format: no
Word alignment: no

0

D0

SB

D0

CB

1

D2

D1

D2

D1

2

D4

D3

reserved

D3

3

D6

D5

reserved

reserved

4

reserved

D7

reserved

reserved

Evaluation in Motorola format

Default mapping for PROFIBUS and Interbus

 

Address

Input data

Output data

Conditions

Word offset

High byte

Low byte

High byte

Low byte

Complete evaluation: don't care
Motorola format: yes
Word alignment: no

0

D3

SB

D3

CB

1

D1

D2

D1

D2

2

D7

D0

reserved

D0

3

D5

D6

reserved

reserved

4

reserved

D4

reserved

reserved

Evaluation in Intel format with word alignment

Default mapping for Lightbus and Ethernet

 

Address

Input data

Output data

Conditions

Word offset

High byte

Low byte

High byte

Low byte

Complete evaluation: don't care
Motorola format: no
Word alignment: yes

0

reserved

SB

reserved

CB

1

D1

D0

D1

D0

2

D3

D2

D3

D2

3

D5

D4

reserved

reserved

4

D7

D6

reserved

reserved

Evaluation in Motorola format with word alignment

 

Address

Input data

Output data

Conditions

Word offset

High byte

Low byte

High byte

Low byte

Complete evaluation: don't care
Motorola format: yes
Word alignment: yes

0

reserved

SB

reserved

CB

1

D2

D3

D2

D3

2

D0

D1

D0

D1

3

D6

D7

reserved

reserved

4

D4

D5

reserved

reserved

Key

Complete evaluation: Additionally to the process data the control and status bytes are showed in the address area
Motorola format: Motorola or Intel format can be set.
Word alignment: in order that the address area of each channel starts always on a word boundary, dummy bytes are added to the process image

SB: Status Byte (appears in the process image of the inputs)
CB: Control Byte (appears in the process image of the outputs)

D0, D1, D2, D3: Bytes for the Counter value (read)
D4, D5, D6, D7: Bytes for the Latch value (read)

reserved: Although this byte occupies space in the process memory, it has no function.
"-": This byte is not used or occupied by the Fieldbus Box.