Status LEDs

Status LEDs 1:

Connection

LED

Display

Meaning

X01:
Stepper motor

S

green

The output stage is enabled.

yellow

If motor is disabled: Motor control in standby

If motor is enabled: warning, configuration error. Check the motor status.

red

Error. Check the Diag Messages

R

green

Motor is turning

red

internal error

X02:
DC link input

V

off

The DC link voltage is not present.

green

The DC link voltage is present.

O

off

The digital output gives a low level.

green

The digital output gives a high level.

X03:
digital inputs
digital output

1

off

Low level at digital input 1.

green

High level at digital input 1.

2

off

Low level at digital input 2.

green

High level at digital input 2.

X04:
Encoder

C

flashes

Encoder track C

A

flashes

Encoder track A