EPP2316-0003

Process image in TwinCAT

 

Connector

Contact 1)

Variable

Diagnostic bit

Process image 1:

 

I

N

P

U

T

0

Process image 2: DIG Inputs
Process image 3: Input 1

-

1

Process image 4: DIG Inputs
Process image 5: Input 2

-

2

Process image 6: DIG Inputs
Process image 7: Input 3

-

3

Process image 8: DIG Inputs
Process image 9: Input 4

-

4

Process image 10: DIG Inputs
Process image 11: Input 5

-

5

Process image 12: DIG Inputs
Process image 13: Input 6

-

6

Process image 14: DIG Inputs
Process image 15: Input 7

-

7

Process image 16: DIG Inputs
Process image 17: Input 8

-

O

U

T

P

U

T

0

Process image 18: DIG Outputs
Process image 19: Output 1

Process image 20: DIG Diag Inputs
Process image 21: Diag Input 1

1

Process image 22: DIG Outputs
Process image 23: Output 2

Process image 24: DIG Diag Inputs
Process image 25: Diag Input 2

2

Process image 26: DIG Outputs
Process image 27: Output 3

Process image 28: DIG Diag Inputs
Process image 29: Diag Input 3

3

Process image 30: DIG Outputs
Process image 31: Output 4

Process image 32: DIG Diag Inputs
Process image 33: Diag Input 4

4

Process image 34: DIG Outputs
Process image 35: Output 5

Process image 36: DIG Diag Inputs
Process image 37: Diag Input 5

5

Process image 38: DIG Outputs
Process image 39: Output 6

Process image 40: DIG Diag Inputs
Process image 41: Diag Input 6

6

Process image 42: DIG Outputs
Process image 43: Output 7

Process image 44: DIG Diag Inputs
Process image 45: Diag Input 7

7

Process image 46: DIG Outputs
Process image 47: Output 8

Process image 48: DIG Diag Inputs
Process image 49: Diag Input 8

1) Contact numbers on ZS2001 connectors.

EPP2316-0008

Process image in TwinCAT

 

Connector

Contact

Variable

Diagnostic bit

Process image 50:

 

X01

1

Process image 51: DIG Inputs
Process image 52: Input 1

-

2

Process image 53: DIG Inputs
Process image 54: Input 2

-

3

Process image 55: DIG Inputs
Process image 56: Input 3

-

4

Process image 57: DIG Inputs
Process image 58: Input 4

-

5

Process image 59: DIG Inputs
Process image 60: Input 5

-

6

Process image 61: DIG Inputs
Process image 62: Input 6

-

7

Process image 63: DIG Inputs
Process image 64: Input 7

-

8

Process image 65: DIG Inputs
Process image 66: Input 8

-

9

Process image 67: DIG Outputs
Process image 68: Output 1

Process image 69: DIG Diag Inputs
Process image 70: Diag Input 1

10

Process image 71: DIG Outputs
Process image 72: Output 2

Process image 73: DIG Diag Inputs
Process image 74: Diag Input 2

11

Process image 75: DIG Outputs
Process image 76: Output 3

Process image 77: DIG Diag Inputs
Process image 78: Diag Input 3

12

Process image 79: DIG Outputs
Process image 80: Output 4

Process image 81: DIG Diag Inputs
Process image 82: Diag Input 4

13

Process image 83: DIG Outputs
Process image 84: Output 5

Process image 85: DIG Diag Inputs
Process image 86: Diag Input 5

14

Process image 87: DIG Outputs
Process image 88: Output 6

Process image 89: DIG Diag Inputs
Process image 90: Diag Input 6

15

Process image 91: DIG Outputs
Process image 92: Output 7

Process image 93: DIG Diag Inputs
Process image 94: Diag Input 7

16

Process image 95: DIG Outputs
Process image 96: Output 8

Process image 97: DIG Diag Inputs
Process image 98: Diag Input 8