Profile-specific objects (0x6000 ... 0xFFFF)

Index 6000 DO Inputs Ch.1

Index

Name

Meaning

Data type

Flags

Default

6000:0

DO Inputs Ch.1

 

UINT8

RO

0x0E (14dec)

6000:01

Input 1

 

boolean

RO

0x00 (0dec)

6000:02

Input 2

 

boolean

RO

0x00 (0dec)

6000:03

Input 3

 

boolean

RO

0x00 (0dec)

6000:04

Input 4

 

boolean

RO

0x00 (0dec)

6000:05

Input 5

 

boolean

RO

0x00 (0dec)

6000:06

Input 6

 

boolean

RO

0x00 (0dec)

6000:07

Input 7

 

boolean

RO

0x00 (0dec)

6000:08

Input 8

 

boolean

RO

0x00 (0dec)

6000:0E

Sync Error

 

boolean

RO

0x00 (0dec)

Index 6010 DO Inputs Ch.2

Index

Name

Meaning

Data type

Flags

Default

6010:0

DO Inputs Ch.2

 

UINT8

RO

0x0E (14dec)

6010:01

Input 1

 

boolean

RO

0x00 (0dec)

6010:02

Input 2

 

boolean

RO

0x00 (0dec)

6010:03

Input 3

 

boolean

RO

0x00 (0dec)

6010:04

Input 4

 

boolean

RO

0x00 (0dec)

6010:05

Input 5

 

boolean

RO

0x00 (0dec)

6010:06

Input 6

 

boolean

RO

0x00 (0dec)

6010:07

Input 7

 

boolean

RO

0x00 (0dec)

6010:08

Input 8

 

boolean

RO

0x00 (0dec)

6010:0E

Sync Error

 

boolean

RO

0x00 (0dec)

Index F000 Modular device profile

Index

Name

Meaning

Data type

Flags

Default

F000:0

Modular device profile

General information for the modular device profile

UINT8

RO

0x02 (2dec)

F000:01

Module index distance

Index distance of the objects of the individual channels

UINT16

RO

0x0010 (16dec)

F000:02

Maximum number of modules

Number of channels

UINT16

RO

0x0002 (2dec)

Index F008 Code word

Index

Name

Meaning

Data type

Flags

Default

F008:0

Code word

 

UINT32

RW

0x00000000 (0dec)

Index F010 Module list

Index

Name

Meaning

Data type

Flags

Default

F010:0

Module list

 

UINT8

RW

0x02 (2dec)

F010:01

SubIndex 001

 

UINT32

RW

0x00000118 (280dec)

F010:02

SubIndex 002

 

UINT32

RW

0x00000118 (280dec)