Object description (MDP 742)

Object description (MDP 742) 1:

EtherCAT XML Device Description

The display matches that of the CoE objects from the EtherCAT XML Device Description. We recommend downloading the latest XML file from the download area of the Beckhoff website and installing it according to installation instructions.

Object description (MDP 742) 2:

Parameterization via the CoE list (CAN over EtherCAT)

The box is parameterized via the CoE - Online tab (double-click on the respective object) or via the Process Data tab (assignment of PDOs).
Please note the following general CoE information when using/manipulating the CoE parameters:

- Keep a startup list if components have to be replaced

- Differentiation between online/offline dictionary, existence of current XML description

- use "CoE reload" for resetting changes

Note

Risk of damage to the device!

We strongly advise not to change settings in the CoE objects while the axis is active, since this could impair the control.