Configuration data (vendor-specific)
Index 801F DRV Vendor data
Index (hex) | Name | Meaning | Data type | Flags | Default |
---|---|---|---|---|---|
801F:0 | DRV vendor data | Vendor-specific data | UINT8 | RO | 0x18 (24dec) |
801F:11 | Amplifier peak current | Amplifier peak current | UINT32 | RW | 0x000031B8 (12728dec) |
801F:12 | Amplifier rated current | Amplifier nominal current | UINT32 | RW | 0x000018DC (6364dec) |
801F:13 | Amplifier thermal time constant | Amplifier thermal time constant | UINT16 | RW | 0x0023 (35dec) |
801F:14 | Amplifier overcurrent threshold | Threshold value for short-circuit detection | UINT32 | RW | 0x000057E3 (22499dec) |
801F:15 | Max rotary field frequency | Maximum rotary field frequency | UINT16 | RW | 0x0257 (599dec) |
801F:16* | Amplifier peak current with fan | Amplifier peak current in operation with fan (EL7411 only) | UINT32 | RW | 0x0000501A (20506dec) |
801F:17* | Amplifier rated current with fan | Amplifier nominal current in operation with fan (EL7411 only) | UINT32 | RW | 0x00002C31 (11313dec) |
801F:18 | Vendor feature bits | Reserved | UINT32 | RW | 0x00000000 (0dec) |
*) Serves only for compatibility to EL7411, no configuration for EJ7411
Index FB13 DRV Key Code
Index (hex) | Name | Meaning | Data type | Flags | Default |
---|---|---|---|---|---|
FB13:0 | DRV Key code |
| UINT8 | RO | 0x01 (1dec) |
FB13:01 | Code |
| OCTET[32] | RW | {0} |