LEDs

LEDs 1:
EJ5101 - LEDs

LEDs (left side)

LED

Color

Display

State

Description

RUN

green

off

Init

State of the EtherCAT State Machine: INIT = initialization of the plug-in module

flashing

Pre-
Operational

State of the EtherCAT State Machine: PREOP = function for mailbox communication and different default settings set

single flash

Safe-
Operational

State of the EtherCAT State Machine: SAFEOP = verification of the Sync Manager channels and the distributed clocks.
Outputs remain in safe state

on

Operational

State of the EtherCAT State Machine: OP = normal operating state; mailbox and process data communication is possible

flickering

Bootstrap

State of the EtherCAT State Machine: BOOTSTRAP = function for Firmware updates of the plug-in module

A

green

on

-

A signal is present at encoder input A.

B

green

on

-

A signal is present at encoder input B.

C

green

on

-

A signal is present at encoder input C.

I 1

red

on

-

Encoder error detection (encoder-specific)
Error encoder signal, I1 is LOW

off

-

Encoder signal OK, I1 is HIGH (connected to GND)

Latch

green

on

-

A signal is present at the latch input.

Gate

green

on

-

A signal is present at the gate input

LEDs (right side)

LED

Color

Display

Meaning

Up (5V)

green

off

Supply voltage incremental encoder (5 VDC) not available

on

Supply voltage incremental encoder (5 VDC) available