Operating system
The Microsoft Windows Embedded Compact 7 operating system is used on the CX8190 Embedded PC. This operating system is optimized for the CX8190 Embedded PC. This means that not all features of Windows Embedded Compact 7 are available.
Security
For reasons of security the CERHOST and TELNET services are deactivated in the delivery state. To reactivate these services, you need a MicroSD card reader.
CERHOST
CERHOST is deactivated by current images on first start-up via the registry file CeRemoteDisplay_Disable.reg, which is located in the folder RegFiles.
To reactivate CERHOST you have to delete the file CeRemoteDisplay_Disable.reg from the folder RegFiles and also the folder Documents and Settings
Then reinsert the MicroSD card in the Embedded PC and reboot. The Embedded PC creates a new Document and Settings directory and then reboots automatically.
The Embedded PC is then accessible again via CERHOST.
TELNET
TELNET is deactivated by current images on first start-up via the registry file Telnet_Disable.reg, which is located in the folder RegFiles.
To reactivate TELNET you have to delete the file Telnet_Disable.reg from the folder RegFiles and also the folder Documents and Settings.
Then reinsert the MicroSD card in the Embedded PC and reboot. The Embedded PC creates a new Document and Settings directory and then reboots automatically.