Types

The CPU module can be equipped with different hardware and software options: "Windows CE" or "Windows Embedded Standard" are available as operating system. The TwinCAT automation software transforms a CX50x0 system into powerful PLC and Motion Control system that can be operated with or without visualisation. Further system interfaces (pre-installed in the factory) or fieldbus connections can be added to the basic CPU module.

Types 1:

The CX 50x0 modules are available in the following types:

CX5010 (1.1 GHz)

Module

E-Bus

K-Bus

no
operating system

Windows Embedded CE 6

Windows Embedded Standard 2009

no
TwinCAT

TwinCAT 2
PLC
runtime

TwinCAT 2
NC-PTP
runtime

TwinCAT 3
XAR

CX5010-0100

X

-

X

-

-

X

-

-

-

CX5010-0110

X

-

-

X

-

X

-

-

-

CX5010-0111

X

-

-

X

-

-

X

-

-

CX5010-0112

X

-

-

X

-

-

X

X

-

CX5010-0115

X

-

-

X

-

-

-

-

X

CX5010-0120

X

-

-

-

X

X

-

-

-

CX5010-0121

X

-

-

-

X

-

X

-

-

CX5010-0122

X

-

-

-

X

-

X

X

-

CX5010-0125

X

-

-

-

X

-

-

-

X

CX5010-1100

-

X

X

-

-

X

-

-

-

CX5010-1110

-

X

-

X

-

X

-

-

-

CX5010-1111

-

X

-

X

-

-

X

-

-

CX5010-1112

-

X

-

X

-

-

X

X

-

CX5010-1115

-

X

-

X

-

-

-

-

X

CX5010-1120

-

X

-

-

X

X

-

-

-

CX5010-1121

-

X

-

-

X

-

X

-

-

CX5010-1122

-

X

-

-

X

 

X

X

-

CX5010-1125

-

X

-

-

X

-

-

-

X

CX5020 (1.6 GHz)

Module

E-Bus

K-Bus

no
operating system

Windows Embedded CE 6

Windows Embedded Standard 2009

no
TwinCAT

TwinCAT 2
PLC
runtime

TwinCAT 2
NC-PTP
runtime

TwinCAT 3
XAR

CX5020-0100

X

-

X

-

-

X

-

-

-

CX5020-0110

X

-

-

X

-

X

-

-

-

CX5020-0111

X

-

-

X

-

-

X

-

-

CX5020-0112

X

-

-

X

-

-

X

X

-

CX5020-0115

X

-

-

X

-

-

-

-

X

CX5020-0120

X

-

-

-

X

X

-

-

-

CX5020-0121

X

-

-

-

X

-

X

-

-

CX5020-0122

X

-

-

-

X

-

X

X

-

CX5020-0125

X

-

-

-

X

-

-

-

X

CX5020-1100

-

X

X

-

-

X

-

-

-

CX5020-1110

-

X

-

X

-

X

-

-

-

CX5020-1111

-

X

-

X

-

-

X

-

-

CX5020-1112

-

X

-

X

-

-

X

X

-

CX5020-1115

-

X

-

X

-

-

-

-

X

CX5020-1120

-

X

-

-

X

X

-

-

-

CX5020-1121

-

X

-

-

X

-

X

-

-

CX5020-1122

-

X

-

-

X

 

X

X

-

CX5020-1125

-

X

-

-

X

-

-

-

X

CX50x0 systems with Windows Embedded Standard 2009 require a Compact Flash card with a minimum capacity of 2 GB.

Instead of Windows Embedded Standard 2009 optionally Windows Embedded Standard 7 P (32 Bit) can be used. The minimum requirement for that is a CX5020 with 1 GB RAM (installed ex factory) and an 8 GB Compact Flash Card.

Types 2:

Software Images

A list of the different software images can be found in the CX1000 Software Documentation.