Disassembling the power supply unit

The CX2000 Embedded PC series is a modular system and enables individual modules to be replaced or removed quite easily. This section describes how to remove devices from the CX2000 Embedded PC series.

Requirements:

Dismantle the embedded PC as follows:

1. Release the DIN rail mounting by pushing the latches outwards with a screwdriver.
Disassembling the power supply unit 1:
2. Pull the orange strap on the power supply unit and gently remove the device from the DIN rail.
Disassembling the power supply unit 2:
3. Lift the bar clips with the aid of a screwdriver and remove the bar clips.
Disassembling the power supply unit 3:
Once the bar clips have been removed successfully, the modules can be separated from each other.

Disposal

The device must be fully dismantled in order to dispose of it. Electronic components must be disposed of according to national electronic waste regulations.