S-0-0086 Torque/force data scaling type

This parameter can be used to select different scaling types for the torque/force data. The drive represents associated parameters at the selected scale. AX5000 always uses percentage scaling (bit 0).

Attributes

Name

Value

Datatype

binary

Data length in bit

16

Decimal point

0

Min value

0

Default

0

Max value

0

Unit

-

Changeable in EtherCAT state

No

Cyclic transfer

No

Device parameter

No

Related to interface revision

No

Bit pattern:

Bit

Meaning

0-2

Scaling method
Scaling method

0 = percentage
1 = reserved
2 = reserved

3

Scaling type
Scaling type

0 = preferred scaling
1 = parameter scaling

4

Units for linear / rotational scaling
Units for linear / rotational scaling

0 = newton [N] or newton metre [Nm]
1 = reserved

5

Reserved

6

Data reference
Data reference

0 = at the motor shaft
1 = at the load

7 - 15

Reserved

S-0-0086 Torque/force data scaling type 1:

For further information please look into the involved IDN:

S‑0-0103, S-0-0079