S-0-0206 Drive on delay time

After torque / force is activated (bit 14, drive status is set) "drive on delay time" is started. The drive follows the command values after the "drive on delay time" has elapsed.

Attributes

Name

Value

Datatype

udec

Data length in bit

16

Decimal point

0

Min value

10000

Default

100

Max value

150

Unit

ms

Changeable in EtherCAT state

PreOp

Cyclic transfer

No

Device parameter

No

Related to interface revision

No

The value of this parameter must be exactly adapted to the motor holding brake used, so that on the one hand operation against the engaged brake is avoided, and on the other hand sagging of the axis is avoided with vertical axes.