Technical data

Nominal motor current

Motor cable length

Servo drive

Motor choke

max. 400 V

≥25 m to 100 m

AX5101, AX5103, AX5106, AX5112,
AX5201, AX5203, AX5206

AX2090-MD50-0012

max. 480 V

>20 m to 100 m

max. 400 V

≥25 m to 50 m

AX5118 and AX5125

AX2090-MD50-0025

max. 480 V

>20 m to 50 m

Data

AX2090-MD50-0012

AX2090-MD50-0025

Nominal voltage

480 V AC

480 V AC

Rated frequency

0 – 60 Hz

0 – 60 Hz

Test voltage cable/cable for 2 s

1770 V DC

1770 V DC

Test voltage cables/housing for 2 s

2700 V DC

2700 V DC

Rated temperature

50 °C

50 °C

Inductance

0.2 mH

0.12 mH

Continuous load operation (S1)

12 A

25 A

Climate category (IEC 60068-1)

25/100/21

25/100/21

Approval

UL 1283 / UL File No. E10122

UL 1283 / UL File No. E10122

Resistance [type]

25 mΩ

15 mΩ

Power loss

5 - 25 W1)3)

10 -35 W2)4)

Weight

2.9 kg

8.5 kg

1)nominal current 1 - 12 A
2)nominal current 18 - 25 A
3)measured at max. cable length of 100 m
4)measured at max. cable length of 50 m

Insertion loss (guide values for Z = 50 Ω) Technical data 1: