Overtemperature and continuous power at 100% duty cycle

If your application requires a higher continuous power than the specified nominal capacity, you can accept this state if a higher brake resistor temperature is permitted. The following diagram shows the overtemperature v. the continuous power.

 

Overtemperature and continuous power at 100% duty cycle 1:

 

Normal operating range,
max. 130%

Permitted operating range,
max. 160%

Inadmissible operating range,
more than 160%

This operating range is recommended for maximum service life and error-free operation.

This operating range is still permitted, although it results in shorter service life with higher failure probability

In this operating range there is a risk of destruction of the brake resistor through overheating. Due to the high temperatures the adjacent components are also at risk.

Note
Destruction of the brake resistor and adjacent components

Always ensure adequate ventilation of the brake resistor, since the temperatures of the housing surface may exceed 200 °C.